The standards are equipped with BNC coaxial connectors with possibility of three- and four- terminals or four-pair terminals connection.
Download MTE series Data sheet here.
| Model |
Nominal value (F) |
Max. deviation (%) | Calibration uncertainty (%) |
Temperature coefficient (ppm/°C) |
Dissipation factor (-) |
Dielectricum |
|---|---|---|---|---|---|---|
| CP 10p | 10 p | 2 | 0.1 | 15 | < 0.001 | Ceramic multilayer or Siver mica |
| CP 100p | 100 p | 0.1 | 0.05 | 15 | < 0.001 | Ceramic multilayer or Siver mica |
| CP 1n | 1 n | 0.1 | 0.02 | 15 | < 0.0005 | Ceramic multilayer or Siver mica |
| CP 10n | 10 n | 0.1 | 0.02 | 15 | < 0.0005 | Ceramic multilayer or Siver mica |
| CP 100n | 100 n | 0.1 | 0.02 | 15 | < 0.0005 | Ceramic multilayer or Siver mica |
| CP 1u | 1 u | 0.1 | 0.02 | 50 | < 0.001 | Polypropylen |
| CP 10u | 10 u | 0.2 | 0.1 | 50 | < 0.005 | Polypropylen |
| CP 100u | 100 u | 0.2 | 0.1 | 50 | < 0.005 | Polypropylen |