Three-phase power/energy calibrator M-103 is generator of accurate AC three-phase voltage and current with calibrated phase shiftamong signals. It contains three voltage and three current channels, which phase shift each of them against others can be set in rango 0 to 360o. Output voltage can be set in two ranges up to 240 V and output current in three ranges up to 10 A. Power in each phase can be set independently. Frequency covers range from 40 Hz to 400 Hz and can be set with resolution 0.01 Hz. Calibrator has very good long life amplitude stability and low distortion which enable calibration of power meters with average, RMS or peak value indication.
Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20 mA and 10 V and pulse counting for direct calibration of various types of power transducers.
Calibrator is suitable for calibration of digital and analogue power meters, energy meters, PF meters, power transducers and others.
| Parameter | Range | Accuracy |
|---|---|---|
| AC voltage in each phase | 6 - 240 V | 0.03 % of value + 0.02 % of range |
| AC current in each phase | 0.1 - 1 A | 0.03 % of value + 0.02 % of range |
| AC current in each phase | 1 - 5 A | 0.04 % of value + 0.02 % of range |
| AC current in each phase | 5 - 10 A | 0.04 % of value + 0.03 % of range |
| Frequency | 40 - 400 Hz | 0.01 % |
| Power in each phase | 0.6 VA - 2400 VA | 0.07% - 0.1% |
| Phase shift between voltage and current (φ) | 0 - 360 ° | 0.1 ° for I > 0.3A, U > 30V, f=50-200Hz 0.2 ° for other setting |
| Power factor in each phase | 0 - 1 LA/LE | |(cos φ +0.1)-cos φ| for I > 0.3A, U > 30V, f=50-200Hz |(cos φ+0.2)-cos φ| for other setting |
| Build in meter voltage function current function pulse counting |
13 V 25 mA 99 999 |
1.5 mV (0.015%) 3 uA (0.015%) -- |
Accuracy of AC power generated by the calibrator depends on actually set voltage, current and power factor. It is calculated by calibrator and is displayed on the front panel display. Accuracy is calculated according to following formula:
| Effective power | dP = dU + dI + dPF |
| Reactive power | dP = dU + dI + dPF* |
| Appearent power | dP = dU + dI |
where
dP is uncertainty of power [%]
dU is uncertainty of set voltage value [%]
dI is uncertainty of set current value [%]
dPF is uncertainty of set PF value (cos) [%]
dPF* is uncertainty of sinj [%]
| Compliance voltage on current outputs | 2.5 V |
| Burden current on voltage outputs | 30 mA |
| Distortion on voltage outputs | < 0.1 % THD |
| Distortion on current outputs | < 0.2 % THD |
| Resolution in voltage/current setting | 5 digits |
| Power supply voltage | 230 V / 50 Hz |
| Outputs | Isolated terminals of current outputs common Lo terminal of voltage outputs |
| Interface | IEEE488 |
| Power line cable | <small>1 pc</small> |
| Test cable 1m | 4 pcs |
| Operation manual | 1 pc |
| Option 140-50 | Current coil x25, x50 |
| Option 10 | Test cable banana-banana 1000V/20A,1m,black |
| Option 11 | Test cable banana-banana 1000V/20A,1m,red |
| Option 40 | Test cable banana-banana 10A,1m,black |
| Option 41 | Test cable banana-banana 10A,1m,red |
| IEEE488 cable 2m | Double shielded 2m IEEE488 cable |